Issue 5.00
2 - 88 Features
prompts.
If the InMail CF has version 2.00 instead of version 2.10 prompt sets installed,
only a single destination Message Notification is available using Notification
Schedule entry 1.
Retry Interval timers are set on a system wide basis only.
The pager dial string is set on a system wide basis only.
Notification settings can be changed using the Telephone Mailbox Option
Interface or system programming only.
When the retries for a particular destination have been met the system will
immediately move to the next destination even if there is only one destination
active.
Once the notification process begins, a new message does not restart the
process if it is already in progress. Once the process ends (e.g., if the message
is acknowledged or the maximum number of callout attempts is reached), the
next new message will restart the process.
The system determines which numbers are internal extensions or external
numbers by the system dial plan settings.
Depending on the system ARS, routing may be needed to properly route
external calls.
If no trunks are available when an outside destination is attempted it is counted
as a Busy No Answer attempt.