Issue 5.00
3 - 434 Programming
47-12-07 Schedule Start Time (Entryxx Start Time)
Use this option to specify the time the Answer Schedule should start. It
applies to Day of the Week (Type 1), Range of Days (Type 2), and Date
(Type 3) schedules. (To make a schedule run continuously, make the same
entry for 47-12-08 Schedule Start Time and 47-12-09 Schedule End Time.)
. See Answer Tables on page 2-45.
Options
HHMM (24-hour clock)
For example:
0130 = 1:30AM
1700 = 5:00PM
Default
Answer Table 1/Schedule 1 = 08:30 (8:30AM)
All other schedules are undefined.
47-12-08 Schedule End Time (Entryxx End Time)
Use this option to specify the time the Answer Schedule should end. It
applies to Day of the Week (Type 1), Range of Days (Type 2), and Date
(Type 3) schedules. (To make a schedule run continuously, make the same
entry for 47-12-08 Schedule Start Time and 47-12-09 Schedule End Time.)
. See Answer Tables on page 2-45.
Options
HHMM (24-hour clock)
For example:
0130 = 1:30AM
1700 = 5:00PM
Default
Answer Table 1/Schedule 1 = 1700 (5:00PM).
All other schedules = 0000 (Undefined).