Reliant Octel 300 Bedienerhandbuch Seite 328

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 504
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 327
Issue 5.00
2 - 320 Features
47-08-03 Time Limit for Dialing Commands (Dialing Timeout)
Enter the new timeout duration (0-99 seconds).
. By default, Automated Attendant callers have 5 seconds to dial commands.
In the event the timeout duration is exceeded or is not programmed, the
following actions occur:
When a Timeout action is programmed, the call routes to that destination.
When a Timeout action is not programmed, the Instruction Menu repeats 3
times and then InMail hangs up.
5. Set the Maximum Length of Instruction Menus:
47-01-03 Subscriber Message Length (Subs Msg Length)
This sets the maximum message length (1-4095 seconds) for Instruction
Menus.
. The default setting is 120 seconds.