Issue 5.00
2 - 92 Features
Entries
1~255 minutes
Default = 15
47-01-11 Wait between Busy non-Pager
Set the time SV8100 InMail waits after it dials a busy non-pager callout
destination, before retrying the callout number.
Entries
1~255 minutes
Default = 15
47-01-12 RNA Non-Pager Callout Attempt Interval
Set the time SV8100 InMail waits, after it dials an unanswered nonpager
callout destination, before retrying the callout number.
Entries
1~255 minutes
Default = 30
47-01-13 Number of RNA rings
If a non-pager callout rings the destination longer than this number of rings,
SV8100 InMail marks the call as unanswered (Ring No Answer) and hangs
up.
Entries
1~99 minutes
Default = 5
47-01-14 Maximum Attempts
Set how many attempts SV8100 InMail retries an incomplete Message
Notification callout. This total includes unacknowledged callouts, callouts to
a busy destination, and callouts to an unanswered destination. This option
applies to pager and non-pager callouts.
Entries
1~99 minutes
Default = 5
47-02-23 All Message Notification Enabled (Subscriber Mailbox)
Use this option to enable or disable notification for the subscriber mailbox. If
disabled, enabling the individual notification entries has no effect.
Entries
0 = Disabled
1 = Enabled
Default = 1
47-06-21 All Message Notification Enabled (Group mailbox)
Use this option to enable or disable notification for the group mailbox. If
disabled, enabling the individual notification entries has no effect.