Reliant Octel 300 Bedienerhandbuch Seite 371

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 504
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 370
Issue 5.00
InMail System Guide 2 - 363
4. Set up the Department Group Mailbox.
47-03-02 Group Mailbox Number (Mailbox Number)
The Group Mailbox number must be the same as the Department Group
master number.
. By default, no Group Mailbox numbers are assigned.
47-03-03 Group Mailbox Type (Mailbox Type)
Assign the Group Mailbox category (
2=Call Routing, 1=Subscriber,
0=Undefined).
. By default, the Group Mailbox type is 1 (Subscriber).
5. Set up the options for the Group Mailbox used for Department Group overflow.
If you entered 2 (Call Routing) for 47-03-03 Group Mailbox Type:
47-07 InMail Routing Mailbox Options on page 3-412.
47-08 Routing Mailbox Call Routing Options on page 3-416.
47-09 Routing Mailbox Announcement Options on page 3-419.
If you entered
1 (Subscriber) for 47-03-03 Group Mailbox Type:
47-06-01 Number of Messages on page 3-403.
47-06-02 Message Playback on page 3-403.
47-06-03 Auto Erase/Save of Messages (Auto Erase/Save) on page
3-404.
47-06-05 Recording Conversation Beep (Rec Conv Beep) on page 3-404.
47-06-06 Message Waiting Lamp (Update MW Lamp) on page 3-405.
47-06-07 Auto Attendant Do Not Disturb (Auto-ATT DND) on page 3-405.
47-06-08 Forced Unscreened Transfer (Forced UTRF) on page 3-405.
47-06-09 Auto Time Stamp on page 3-406.
47-06-10 System Administrator (System Admin) on page 3-406.
47-06-11 Dialing Option on page 3-406.
47-06-12 Next Call Routing Mailbox (Next CR Mbox) on page 3-407.
Operation
Not applicable