Issue 5.00
1 - 4 Quick Setup
SECTION 4 BASIC FUNCTIONS WITHOUT MAIN GREETING
To make the InMail answer, the following programming must be done. The example
shown is for a 8-port InMail. Extension, Group and Pilot Numbers shown can be
adjusted as needed per installation requirements.
47-01-17 Set first port of In-Mail to 25, changing this PRG requires a CHS2U GW
reset.
10-09-01 Verify at least one resource is set to ICM/TRK or Common.
11-07-01 Set TEL Group Pilot 64 to 555 (Note: digit 5 is set to 4 digits by default).
Never use Group 1, as this is the default group for all extensions.
15-03-01 Set extension 224~231 to DP
15-03-03 Set extension 224~231 to Special.
16-02-01 Put 224~231 in Group 64.
16-02-02 Assign priorities 1~8 to 224~231.
16-01-01 Set Group 64 name to Voice Mail.
16-01-04 Set Group 64 to Circular.
16-01-10 Set Group 64 to Busy/No Answer.
45-01-01 Set to Group 64.
SECTION 5 ENABLE THE MAILBOXES FOR ALL INSTALLED EXTENSIONS
Since by default only extensions 200-263 have Subscriber Mailboxes, you should
enable additional Subscriber Mailboxes for all installed extensions.
To enable additional Subscriber Mailboxes:
1. In 47-02-01 Mailbox Type, enter 1 to enable a Subscriber Mailbox for each
extension as a ‘Person’ mailbox.
To make programming easier, consider associating a mailbox number with a station
port. For example, mailbox 1 should correspond to port 1, which in turn corresponds
to extension 200.
2. In 47-02-02 Mailbox Number, select the extension number to be associated with
the mailbox you are programming.
Normally, mailbox 1 should use Mailbox Number 200, mailbox 2 should use Mailbox
Number 201, etc.