BULLETIN 60
INSULATION BLANKETS
GENERAL The purpose of an insulation blanket is to reduce the standby heat loss encountered
with storage tank heaters.
Most modern water heaters have adequate factory installed insulation, the use of an
after market insulation blanket is no longer recommended by most experts. While
the use of an external insulation blanket will not void the warranty, the water heater
manufacturer explicitly disclaims any liability for problems associated with the use of
insulation blankets.
NOTE: A few local energy codes may still require the use of insulation blankets on
waters heaters. Be sure to follow all installation instructions, cautions, and warnings for
the insulation blanket as well as the cautions and warning of the water heaters owners
manual.
NOTES Should you choose to apply an insulation blanket to this heater, you should follow these
instructions. Failure to follow these instructions can restrict the air ow required for
proper combustion, resulting in re, asphyxiation, serious personal injury or death.
Do not cover the outer door, thermostat or temperature & pressure relief valve.
When installed the insulation blanket will cover important safety and operation
labels. Obtain new warning and instruction labels from the Technical
Information Center listed in the owners manual. The replacement labels must
be placed on the blanket in the location of the original labels on the water
heater jacket.
Do not cover the instruction manual. Keep it on the side of the water heater or
nearby for future reference.
Do not apply insulation to the top of the water heater, as this will interfere with
safe operation of the draft hood.
Do not allow insulation to come within 2” of the base of the water heater to
prevent blockage of combustion air ow to the burner. The combustion air
openings in the base of the water heater must NOT be obstructed.
Inspect the insulation blanket frequently to make certain it does not sag,
thereby obstructing combustion air ow.