Reliant FVIR GAS WATER HEATER Technical Information Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
3
Your safety and the safety of others is extremely important in the servicing of this water heater. Many safety-
related messages and instructions have been provided in this handbook and on your water heater to warn you
and others of a potential hazard. Read and obey all safety messages and instructions throughout this handbook.
It is very important that the meaning of each safety message is understood by you and others who service this
water heater.
The information contained in this handbook is designed to answer commonly faced situations encountered
in the operation of the standard Residential Gas product line and is not meant to be all-inclusive. If you are
experiencing a problem not covered in this handbook, please contact the Technical Information Center listed on
the cover of this handbook for further assistance. Additional information is also available on the web site listed on
the cover of this handbook. This handbook is intended for use by licensed plumbing professionals and reference
should be made to the Installation Instructions and Use & Care Guide accompanying the product. This handbook
contains supplemental information to the Installation Instructions and Use & Care Guide.
When servicing residential water heaters, it is essential that you return the unit to a safe condition before you
leave the site. All original components must be re-installed and all safety measures must be implemented. In
addition, the recommended water temperature setting is 120° F.
IMPORTANT: It is recommend that on every service call an inspection & cleaning of the base ring lter
and ame arrestor be performed. See page 19.
Tools Required (for servicing gas models):
Phillips head screw driver
3/8, 7/16, & 3/4 inch open end wrenches
3/16 inch Allen wrench
11/16 inch – 6 point – socket – for anode removal
electrical multimeter (with alligator leads)
digital or analog manometer
gas pressure gauge
water pressure gauge
• thermometer
tubing cutter if pilot tube is to be replaced
hose – to drain tank
container – to measure gallons per minute flow
SERVICE HANDBOOK
Digital manometer shown.
Seitenansicht 2