RESIDENTIAL GAS AND ELECTRIC WATER HEATER
TROUBLESHOOTING and SERVICE HANDBOOK
RELIANCE Water Heater Company Technical Training Department
©2006 Ashland City, TN
8
Temperature: Two metal probes mounted
onto the back of the control are immersed
inside the tank water. One probe (the
shorter) acts as a temperature high limit. If
water gets excessively hot, a sensor within
the probe opens, interrupts the small
electrical current to the gas valve, and gas
flow through the control is interrupted. If this
safety sensor opens, the entire control must
be replaced.
The longer probe contains a metal rod that
expands and contracts as water temperature
around the probe cools and heats. As the
rod expands, it pushes against a lever
actuated gas valve. If the regulator is
pushed sufficiently, gas flow is interrupted to
the main burner. Adjusting the temperature
dial changes the distance the rod must
expand or contract to open or close the gas
valve.
Gas: When you prepare to light the pilot,
you are instructed to turn the top
knob to the pilot position and depress
the knob. When the knob is
depressed gas will flow to the pilot
burner only. You then have to
(manually) ignite this pilot gas. When
the pilot is lit, the flame must heat the
thermocouple until it generates
sufficient electricity to the gas valve
to allow you to release the knob while
gas continues to flow to the pilot.
When the top knob is turned to the
“ON” position, gas is also available to
the main burner if the thermostat calls
for heat.
Residential Gas - continued