RESIDENTIAL GAS AND ELECTRIC WATER HEATER
TROUBLESHOOTING and SERVICE HANDBOOK
RELIANCE Water Heater Company Technical Training Department
©2006 Ashland City, TN
38
Residential Electric – continued
Cold tank of water
Single Electrical Service
Single Phase
A-7 Circuit
Post 1995
Fused Disconnect
Power to Upper High Limit 1,
and Upper Thermostat 3
Upper High Limit 1, 2 is Closed.
Upper Thermostat 3, 4 is Open
Upper Thermostat 1, 2 is Closed
Upper Element is On
No Power
to Lower
High Limit
Terminal 1
Top 1/3 of Tank is Heated
Upper Thermostat 1, 2 Opens
Upper Thermostat 3, 4 Closes
Power Flows Between
Upper Thermostat 4 and
Lower High Limit L1
Lower High Limit L1 and
Lower Thermostat T2 is Closed
Power to Upper High Limit 3
and Lower High Limit L3
Upper High Limit 3, 4 is Closed
Lower High Limit L3, L4 is Closed
Lower Element Heats Bottom 2/3 of Tank