RESIDENTIAL GAS AND ELECTRIC WATER HEATER
TROUBLESHOOTING and SERVICE HANDBOOK
RELIANCE Water Heater Company Technical Training Department
©2006 Ashland City, TN
15
Residential Gas – continued
Exhaust Venting Notes
Follow current National Fuel Gas Code requirements for proper installation.
“D” – Typically, same or larger diameter as Draft Hood
outlet
“L” – Horizontal piping slopes upward ¼” per foot from
heater to chimney or vertical vent
Length of horizontal not more than 75% of “H”
“H” – Not less than 5 feet
Maximize vertical distance to first elbow
Refer to the Technical Bulletin titled “Venting
Techniques that Eliminate Pilot Outage” or page 70 of
this handbook.
FLAMMABLE VAPOR IGNITION RESISTANT DESIGN
This section will address the changes brought about by the introduction of FVIR compliant products. Other
than items mentioned here, the construction, installation, and service will remain the same as discussed in
the primary handbook.
The FVIR acronym stands for "Flammable Vapor Ignition Resistant." The RELIANCE products are based on
"Corderite Combustion Containment" known as “C3 Technology™” . The C3 Technology design features a
sealed (from non designated air intake openings) combustion chamber and a "flame arrestor" component.
This class of residential gas water heaters meet the new ANSI standards and testing protocols (ANSI
Z21.10.1) established to deal with the accidental or unintended ignition of flammable vapors, such as those
emitted by gasoline. Virtually all gas-fired, atmospherically vented, residential water heaters manufactured
in the United States with BTU ratings of 75,000 or less are required to meet this new ANSI standard
effective July 1,2003. The current implementation schedule for C3 TECHNOLOGY compliant residential
gas-fired products is shown in the following table. These dates are subject to change.