Venting System Inspection
The water heaters internal flue must
be inspected annually to be certain it is
clean by removing the draft hood and
flue baffle.
When reinstalling the flue baffle
make certain it is hung securely by its
hanger at the top of the flue way.
Reinstall the draft hood.
Inspect the gas venting system and the
chimney.
Make certain the vent connector
from the draft hood to the chimney
is properly positioned and securely
attached.
If after inspection of the vent system
you found soot or deterioration; call
the local gas utility to correct the
problem and clean the flue, or replace
the flue, flue baffle, and venting
system before resuming operation of
the water heater.
Test for spillage at the draft hood
relief opening after 5 minutes of
burner operation. Use a flame of a
match or candle or smoke.
Burner Inspection
Visually inspect the pilot burner and
main burner annually.
Through the sight glass, inspect the
pilot burner flame with the main
burner off and inspect the main
burner while firing.
If any unusual burner operation is
noted, the water heater should be shut
off until qualified service assistance
can be obtained.
The burner operates in radiant mode
and glows bright orange when burning
correctly. Allow approximately 30
seconds after turning on for the burner
to reach the radiant mode
CAUTION: For your safety,
cleaning of the burner must be
performed only by qualified service
personnel. The burner chamber is
a sealed area. If the burner inner
door, lower air box, or inner door
burner assembly are removed, the
inner door gaskets, burner access
door gasket, and transition pan
gasket must be replaced.
For cleaning, remove the inner door
and inner door burner assembly from
the water heater. A vacuum cleaner
can be used on the burner and inside
the water heater. The burner can
also be cleaned by blowing air over
the burner surface. DO NOT allow
any large debris to remain inside the
burner. Refer to page 23.
Proper burner and pilot burner
pattern.
Care and cleaning of the water heater
Vacation and Extended Shut-Down
If the water heater is to remain idle for
an extended period of time, the power
and water to the appliance should
be turned off to conserve energy
and prevent a build-up of dangerous
hydrogen gas.
The water heater and piping should be
drained if they might be subjected to
freezing temperatures.
After a long shut-down period, the
water heaters operation and controls
should be checked by qualified service
personnel. Make certain the water
heater is completely filled again before
placing it in operation.
NOTICE: Refer to the
Hydrogen Gas Caution in the
Operating Instructions.
Anode Rod
This water heater is equipped with
an anode rod designed to prolong
the life of the glass lined tank. The
anode rod is slowly consumed, thereby
eliminating or minimizing corrosion of
the glass lined tank.
Water sometimes contains a high
sulfate and/or mineral content and
together with cathodic protection
process can produce a hydrogen
sulfide, or rotten egg odor in the heated
water. Chlorination of the water supply
should minimize the problem.
NOTICE: DO NOT remove
the anode rod from the water
heater’s tank, except for
inspection and/or replacement,
as operation with the anode rod
removed will greatly shorten
the life of the glass lined tank
and will exclude warranty
coverage.
Gas ame
should be visible
on entire burner
surface.
Pilot
Flame
!