Operating the water heater
Water Temperature Setting
Maximum water temperatures occur just
after the burner has shut off. To determine
the water temperature, turn on a hot water
faucet and place a thermometer in the
water stream.
The reference mark p on the rim of the
temperature dial, represents an approximate
water temperature of 120°F(49° C).
The reference mark
A
represents an
approximate water temperature of 130°F
(54° C).
Each reference mark above or below these
points indicates an approximate change of
10°F.
To adjust the temperature, turn the
temperature dial to an initial setting of
120°F.
A condition known as “stacking” or
“layering” can occur when a series of short
and frequent hot water draws are taken.
The hottest temperature water will be at the
top of the tank, closest to the outlet pipe
delivering hot water to the home.
Stacking can cause this top layer of water
to be hotter than the water toward the
bottom of the tank near the gas control
(thermostat).
Therefore, always remember to test the
water temperature with your hand before
use and remember that hotter water
increases the risk of scald injury.
Also, always supervise young children or
others who are incapacitated.
The gas control (thermostat) is constructed
with a built in safety shut-off device
designed to shut off the gas supply to the
burner if the pilot flame is extinguished for
any reason.
The gas control (thermostat) is also
equipped with a single use gas shut off
device that will shut off the gas supply
to the burner if the water heater exceeds
normal operating temperatures. Refer to the
(Before You Call For Service) section of
this manual, or contact your dealer.
!
WARNING: Should overheating occur
or the gas supply fail to shut off, turn off
the manual gas control valve to the
appliance.
If the water heater has been subjected to
fire, flood or physical damage, turn off
the manual gas (shut-off) valve, and do
not operate the water heater again until it
has been checked by a qualified service
technician.
NOTICE: DO NOT use this appliance
if any part has been under water.
Immediately call a qualified installer or
service agency to replace a flooded water
heater. Do Not attempt to repair the
unit! It must be replaced.