Seitenansicht 615
12-52
Installation and Maintenance
Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Action Octel
Overture 200/300 Description and Response
To
log on to the Octel Overture 200/300.
At the @ prompt enter the slot number for the removed drive. The VCU
tests the slot and updates its status record.
Repeat
DSKTST
for each drive removed.
V
iews the status of all drive slots.
@
SLOT: 1 2 3 4 5
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
SHELF B| | | System 1 | System 2 | |
| | | ID:S1 ACTIVE | ID: S2 ACTIVE | |
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
SLOT: 1 2 3 4
+––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
SHELF C| Voice 1 | Voice 2 | Voice 3 | Voice 4 |
| ID: UNKNOWN | ID: EMPTY | ID: EMPTY | ID: EMPTY|
+––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
The
following menu is presented:
CURRENT STATUS
Slot Type ID Status Configured
––––––––––––––––––––––––––––
B3 System1 S1 ACTIVE Configured
B4 System2 S2 ACTIVE Configured
C1 Voice 1 –– ACTIVE Configured
DISK OPTIONS
1. ADD DISK
2. REMOVE DISK
3. REPLACE A DISK
4. RESTORE SYSTEM
5. UPGRADE LANGUAGES
Select option to be performed
(1–5 – Empty line = EXIT)
:
After
several seconds, the Octel Overture 200/300 displays
Remove drive in slot C1 and repeat DISKO REMOVE command.
8. Press

9. @DSKTST

10. @DSKMAP

Choose
the Correct Disk Option
11. @DISKO

12. Choose
option 2 —
REMOVE DISK.
Seitenansicht 615
1 2 ... 611 612 613 614 615 616 617 618 619 620 621 ... 667 668

Kommentare zu diesen Handbüchern

Keine Kommentare