10-16
Installation and Maintenance
V
olume
Octel Overture 200/300 Serenade 3.0
PB60014–01
The
ST CARD
command shows the status of the card:
dtic>ST CARD
––––– Channel Status – ALL –––––––––––––––––––––––––––––––––––––––––––––––––––––––
CARD STATE: UP
SEQUENCER PC: C2
CLOCK MASTER: Enabled
CLOCK ACTIVE: Enabled
This
example shows normal card status. In this example, the card is enabled to be the synchronization
receiver of the master clock.
The
ST 1
command shows the port status for port 1 (channel 1):
dtic>ST 1
––––– Channel 01 Status ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
RECEIVE TRANSMIT
ABCD: 0001 ABCD: 0001
OTHER:
CHANNEL STATE: ON HOOK
SEQUENCER PC: 02
This
example shows normal port status for port 1. The port is idle and is transmitting and receiving the
on-hook code.
The
LIST STATS
command gives a count of errors seen by the trunk:
dtic>LIST STATS
ts_oof_cnt = 0
ts_oof_crc_cnt = 0
ts_lcv_cnt = 0
ts_bit_slip_cnt = 0
ts_crc_fail_cnt = 0
ts_fas_err_cnt = 0
ts_febe_cnt = 0
ts_oof_cas_cnt = 0
COFA cnt = 0
CAS COMFA cnt = 0
HDB3 Detect cnt = 1
PCM Frm Slip cnt = 0
The
following gives basic information about the fields for these error counts.