Hardware
Replacement 9-31
Octel Overture 200/300 Serenade 3.0
PB60014–01
Figure 9-20
Octel Overture 300 Power Supply Assembly
Circuit Breaker
Captive ChassisĆ
Mounting Screws
Caution!
The power supply unit is sensitive to static electricity
.
Do not attempt the following procedures without
wearing an antistatic wrist strap.
Removing the Power Supply Unit
Use
the following procedure to remove the power supply unit:
Caution!
The power supply unit is
not
hot pluggable.
Do not
remove the power supply unit when it is ON.
1.
Unlock and open the door of the cabinet.
2.
Put on an antistatic wrist strap. Connect it to an unpainted portion of the cabinet.
3. T
urn OFF the power to the message server at the switch on the front of the power supply unit. The
switch for the power supply unit is a circuit-breaker rocker switch.
On the Octel Overture 200, the switch is OFF when the bottom of the rocker
, marked 0, is pressed in.
The switch is ON when the top of the rocker
, marked 1, is pressed in.
On the Octel Overture 300, the switch is OFF when the side of the rocker
, marked 0, is pressed in.
The switch is ON when the side of the rocker
, marked 1, is pressed in.