8-22
Installation and Maintenance
V
olume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
41. Visual
Mailbox
Hardwar
e Err
or
(LAN HE)
Command link
interface LAN is
malfunctioning or has
detected a network
error
This is a V
isual Mailbox error
. First check
that V
isual Mailbox is functioning properly
.
If it is, this is a false alarm or the condition
has corrected itself.
Check to see if the cable from the Octel
Overture 200/300 to the Gateway is
properly connected and secured. Restart the
Gateway
. If the problem still exists, replace
the CLI board in the Gateway
.
3
DATA-1 = LAN ERROR TYPE AS FOLLOWS:
01 = NO RESPONSE FROM LAN CONTROLLER AFTER CONTROLLER
RESET
02 = NO INTERRUPT RECEIVED FROM LAN AFTER CONTROLLER
ENABLED
03 = INCORRECT ID STRING STORED BY CONTROLLER AFTER RESET
DATA-2 = FIRST BYTE OF ID STRING (SHOULD BE D1 HEX)
DATA-3 = SECOND BYTE OF ID STRING (SHOULD BE NODE ID)
20 = PACKET TRANSMISSION WAS NOT ACKNOWLEDGED AFTER 5
SECONDS
DATA-2 = DESTINATION NODE ID
21 = NETWORK RECONFIGURATION OCCURRED DUE TO TOKEN RING
INACTIVITY
2
Seitenansicht 391