Seitenansicht 390
System
Errors and T
raf
fic Pegs 8-21
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
38. Disk
Defect Boot
Region
Defect in secondary
bootstrap (Xboot)
region
Attempt to reload the software code from
the floppy diskette to the hard disk. If error
repeats, replace the hard disk indicated in
DAT
A-1. If error repeats again, call your
technical support center
.
3
DATA-1 = LOGICAL DRIVE ID WITH DEFECTIVE XBOOT
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED
39. Disk
Defect File
System Region
Defect in file system
region of a system
disk
Attempt to reload the software code from
the floppy diskette to the hard disk. If error
repeats, replace the hard disk indicated in
DAT
A-1. If error repeats, call your
technical support center
.
3
DATA-1 = LOGICAL DRIVE ID WITH DEFECTIVE FILE SYSTEM
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED
40. Non-Media
Disk
Error
Non-media disk error
Call your technical support center to have
information interpreted.
DATA-1 = DRIVE ID AND SEVERITY INDICATION
01 = NON-FATAL ERROR, DRIVE 1
02 = NON-FATAL ERROR, DRIVE 2
03 = NON-FATAL ERROR, DRIVE 3
04 = NON-FATAL ERROR, DRIVE 4
05 = NON-FATAL ERROR, DRIVE 5
06 = NON-FATAL ERROR, DRIVE 6
1
81 = FATAL ERROR, DRIVE 1
82 = FATAL ERROR, DRIVE 2
83 = FATAL ERROR, DRIVE 3
84 = FATAL ERROR, DRIVE 4
85 = FATAL ERROR, DRIVE 5
86 = FATAL ERROR, DRIVE 6
3
DATA-2 = SCSI SENSE KEY
DATA-3 = SCSI SENSE CODE
DATA-4 = NOT USED
3
Seitenansicht 390
1 2 ... 386 387 388 389 390 391 392 393 394 395 396 ... 667 668

Kommentare zu diesen Handbüchern