System
Errors and T
raf
fic Pegs 8-19
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
34:Power-ON
Diagnostic
Err
or
(continued)
Selftest for VCU.
DAT
A-1 through
DAT
A-4 designate
errors found
Replace VCU.
3
DATA-3
Bit 0:
Port Controller failed diagnostic selftest.
Bit 1:
Port Controller interrupt functionality failed.
Bit 2:
Port Controller ALU failed.
Bit 3:
Port Controller carry logic failed.
Bit 4:
Port Controller failed to return diagnostic acknowledgement.
Bit 5:
Port Controller failed PLA
Y/RECORD loop back test.
Bit 6:
Port Controller failed Silence register loop back test.
Bit 7:
DMA controller error detected.
DATA-4
Bit 0:
W
atch Dog T
imer circuit failed.
Bit 1:
Master interrupt circuit failed.
Bit 2: Control Bus Status Register circuit failed.
Bit 3:
SCSI Controller circuit failed.
Bit 4:
Undefined.
Bit 5:
Undefined.
Bit 6:
Undefined.
Bit 7:
Undefined.
36.
System RAM
Error
Cache module found
an error with system
RAM, CPU and/or
VCU.
Call your technical support center for
remedy.
3
The DA
T
A-1 field specifies the type of error
. DA
T
A-2 through DA
T
A-4 are data
associated with the error
.
DATA-1 = ERROR CODE:
01 = FIRMWARE REPORT OF RAM SIZE NOT EVEN MEGABYTE
02 = CANNOT R/W MEM AS REPORTED BY FIRMWARE, SEE DATA-2
DATA-2: (D) = MEGABYTES WHERE ERR, WHEN DATA=1 OR 2
03 = RAM SIZE LESS THAN STANDARD SIZE OF 5 MEG FOR THE
OCTEL OVERTURE 300 AND 2 MEG FOR THE OCTEL OVERTURE 200
(slot = CPU)