System
Errors and T
raf
fic Pegs 8-15
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
33:Line
Card
Hardwar
e Err
or
Error logged by
selftest when start
LSP reply was
received with either
an error status or an
unexpected OK status
(e.g., Slot is empty or
already reported
down)
Contact your technical support center
. 3
The DA
T
A-1 field specifies the type of error
. DA
T
A-2 and DA
T
A-3 are data associated
with the error
.
DATA-1 = REPORTED STATUS
00 = START LSP REPLY RECEIVED WITH EITHER AN ERROR
STATUS OR AN UNEXPECTED OK STATUS
(e.g.
slot is empty or already reported down.)
DATA-2 = REPORTED STATUS
00 =
LSP SUCCESSFULL
Y STARTED
01 = SCSI ERROR WHILE LOADING LSP
DATA-4 = VCU ERROR CODE
02 = CARD TYPE IN SLOT DOES NOT MATCH
CONFIGURED TYPE
DATA-4 = CARD TYPE ACTUALLY INSTALLED
IN SLOT
03 = CONTROL BUS ERROR – SLOT EMPTY OR
CARD NON-RESPONSIVE
04 = FILE SYSTEM READ ERROR ACCESSING LSP
IMAGE
05 = CARD IN SLOT REPOR
TS F
ATAL DIAGNOSTIC
ERROR
DATA-3 = SUPPLEMENTAL CARD STATUS
06 = BAD START LSP REQUEST
89 = LIC REPORTED LIC IMAGE CHECKSUM
ERROR
DATA-3 = CURRENT SLOT STATE
00 = EMPTY (UNCONFIGURED)
01 = WAITING FOR INITIAL START LSP REPLY
02 = RUNNING
03 = ERROR
01 = NO PORTS CONFIGURED FOR LINE CARD
02 = LINE CARD DISALLOWED BY OCC
03 = TOTAL PORTS > ALLOWED BY OCC
04 = ERROR WRITING START LSP REQUEST TO VCU
05 = DISK ERROR WHEN SEARCHING FOR LSP CODES