Reliant Octel 200 and Octel 300 Message Servers PB6001401 Bedienungsanleitung Seite 377

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 668
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 376
System
Errors and T
raf
fic Pegs 8-7
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
DATA-2 = 00 = NO VOICE FILE SLOTS LEFT
01–06 =
LOGICAL DRIVE ID THAT IS FULL
0a = PROMPT AREA FULL
0b
= NO DISK WITH SUFFICIENT SPACE AVAILABLE
0c = SYSTEM RECORDING LIMIT EXCEEDED (ZERO HOUR DRIVES)
DATA-3 = NOT USED
DATA-4 = NOT USED
11: Disk
Initialization
Failure
VCU could not
successfully initialize
the disk(s).
Contact your technical support center
. 3
DATA-1 = REASON:
01 = NO SYSTEM DISK FOUND
02 = NO VALID FILE SYSTEM FOUND
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED
12:CPU
Parity
Parity error occurred
in CPU memory area.
If error repeats, replace power supply unit.
3
DATA-1 FROM I/O ADDRESS 6A (ERR.ADDR2)
BIT 0, 1, 2 = CONTEXT REG IN USE ON ERROR
DATA-2 FROM I/O ADDRESS 69 (ERR.ADDR1)
HIGH ADDRESS ON PARITY ERROR
DATA-3 FROM I/O ADDRESS 68 (ERR.ADDR0)
LOW ADDRESS ON PARITY ERROR
DATA-4 CONTENTS OF CONTEXT REG DESIGNATED BY DATA-1
14:VCU
initial
checksum err
or
VCU code checksum
incorrect
Contact your technical support center
. 3
15:
System Status
Error
T
emperature or
voltage out of range
Check DA
T
A-1 for information pertaining
to what is out of range and perform
corrective action.*
3
*T
o correct cabinet temperature, check the filter
, fan, room
temperature, etc. Be sure there are at least six inches between
cabinet and the wall. If Type 15 errors (with DA
T
A-1=01) still
appear
, replace the CPU card. For T
ype 15 errors (with
DAT
A-1=02, 03, 04, 05, 06, 0A, or 0B), voltage cannot be
adjusted; recommended action is to replace the power supply
unit.
Seitenansicht 376
1 2 ... 372 373 374 375 376 377 378 379 380 381 382 ... 667 668

Kommentare zu diesen Handbüchern

Keine Kommentare