Reliant Octel 200 and Octel 300 Message Servers PB6001401 Bedienungsanleitung Seite 285

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 668
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 284

Commands 6-55
Octel Overture 200/300 Serenade 3.0
PB60014–01
.L APP
LST:
APPLICATION DELAY TABLE
INDEX DELAY (msec.)
00
1 7000
2 5000
3 500
4 3000
5 1200
6 1000
7 30000
8 1600
.
.
.
.
251 0
252 0
253 0
254 0
255 0
Modify Command
Use
the
MODIFY
command to change application delays. The message server prompts for the
application-delay index to be modified. Refer to the Modifiable Application–Delay Indexes section in
this chapter; only the delays that are listed can be modified at the Maintenance level. Enter the
application-delay index number
. T
ype the new value, and press

. The message server displays the
new value.
The delay values are entered in milliseconds and rounded to the nearest 20 ms value.
The following is an example of Application Delay Index 8 being modified to 1000 ms (1 second).
.M APP
Enter APPLICATION DELAY index.
MOD:8
Enter new value (in MILLISECONDS) for APP DELAY 8.
Note: Will be rounded to the nearest 20 MSEC.
(0–1310700 MSEC,
(0
means Infinite, empty line = 800 )
MOD:1000
DELAY set to 1000 MSEC.
Caution!
Changing
an Application Delay from a nonzero value
to zero should
never
be done. A zero value sets an
infinite timeout that could result in permanently
locking up a port.
.M APP
Seitenansicht 284
1 2 ... 280 281 282 283 284 285 286 287 288 289 290 ... 667 668

Kommentare zu diesen Handbüchern

Keine Kommentare