Commands 6-45
Octel Overture 200/300 Serenade 3.0
PB60014–01
How To Modify Application Delays
You
should only modify those application-delay indexes for PBX tones that fail. Before modifying an
application-delay index, use the
PRT (PRINT
TONE
) command and COS Attribute 70 — MEASURE
PBX T
ONES, to determine the correct timing value. Use the following steps:
1.
Assign COS Attribute 70 to a test mailbox that has an extension number for a telephone set located
near the terminal.
When a mailbox with COS Attribute 70 is called, the Octel Overture 200/300 dials the extension
number
, stays on line for 10 tone changes, and then hangs up. During this call, you can determine the
tone cadence of the PBX.
The extension called should
not
be set to forward on ring-no-answer
, busy
, or fast busy
. Other
features, such as camp-on, must be disabled. This could give a false tone cadence.
2.
Select an
Octel Overture 200/300 port and at the @ prompt, type
PRT x

For this command,
x
is the port number to be used.
3.
Call that port’
s extension number
.
4.
When the message server answers, dial the test mailbox number
.
The
PRT
command monitors and displays the DTMF tones dialed by the caller, the DTMF tones
dialed by the Octel Overture 200/300, and the call-progress tones from the PBX to the terminal. This
command is a real-time command and can be initiated on only one port at a time. The information is
not stored.
If the tones do not show on the screen when the
PRT
command displays the DTMF events, at
the @ prompt, type
C S

5.
Repeat steps 2 through 4. If executing the
C S
command does not help, contact your technical
support center
.
The
PRT
command should be initiated for any call condition that fails, such as when the message
server calls an extension that is sending a ringback but the message server detects an answer
condition.
The following example displays tone information when the Octel Overture 200/300 screens a call to
a ring-no-answer extension that fails. Refer to the Miscellaneous Commands section in this chapter
for a list of Print T
one output types.