6-32
Installation and Maintenance
Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
ERR = Disk
has non-recoverable error
VLD =
Disk part of configuration, but needs rebuild.
UNK =
Disk is valid, but not part of this configuration
INV =
Disk does not have valid configuration block
WPD =
Disk slot is write protected
phy =
physical state of the disk
ALV =
Disk is alive
ERR =
Disk has error
ILL =
Disk is not a valid disk for the model defined
vendor =
Disk manufacturer details
prod_ID =
Disk manufacturer details
rev =
Disk manufacturer detail
Mb =
Physical size of the disk in Megabytes
phy =
Physical size of the disk in disk blocks
/log =
Logical size of the disk in disk blocks
MB =
Logical size of disk in Megabytes
h/k =
OEM identification/ Key revision (1=Non COD, 3=COD)
h = OEM key: 0/1 = Octel and 2/3/5 = OEM
k = COD/non-COD: 1 = non-COD and 3 = COD
A COD drive cannot be copied to a non-COD drive.
Line-Interface-Card
Diagnostics
Three
online diagnostic tests can be used to test the line interface cards (LIC). The first test is performed
periodically during normal message server operation. It is used to check the analog
(voice) path of the
LIC. The second test is the ring detection/PBX connection test. The third test is the ring-through test.
These tests are described in the following sections.
Tone/DTMF/Beep Test
Use
the
TEST LINE 1
command to test line 1. T
o run the test, turn the terminal or teleprinter ON. At
the @ prompt, type
TE L 1

This
test runs in sequence on each of the installed ports.
Use the
TEST LINE 5
command to test line 5 for a specific port. At the @ prompt, type
TE L 5 x

For this command,
x
is the specific port number in HEX.
A hybrid transformer is used on the LIC to check tone generation and detection circuitry
. A tone is applied
to the hybrid transformer and, as it is being reflected, the tone detector is turned ON. A comparison is made
to see whether the tones sent match the tones detected. The test sequence continues, through all assigned
ports. If a test tone sent is not received correctly
, an error is entered in the Hardware Error T
able.
Some PBXs have the capability of running diagnostics on their ports. The diagnostics can cause the Octel
Overture 200/300’
s self-test to fail and place the Octel Overture 200/300 port in TST (test) mode, taking
the port out of service. The port remains in TST mode until the self-test runs again and can put the port in
service or until the message server is restarted. In cases of conflict with PBX diagnostics, the self-test can
be disabled in the SLOTS T
able. Consult with Octel before you set the self-test to NO in the SLOTS T
able.