Reliant Octel 200 and Octel 300 Message Servers PB6001401 Bedienungsanleitung Seite 172

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 668
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 171
4-54
Installation and Maintenance
Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
8. Busy
out the PBX extension identified in step 6 above.
9.
Continue the process from step 3 until all ports have been busied out.
Testing
Fail-Safe Operation
The
fail-safe port operation test comprises the all-ports-busy condition and the ring-no-answer condition.
All
Ports Busy
Perform
the following steps for the all-ports-busy test:
1.
While all ports are busied out, use telephone A to enter the extension number or access code of the
hunt group.
2.
Does the call overflow to the correct answering extension as determined for fail-safe operation?
YES Continue.
NO
Determine the cause and correct the problem before continuing.
Some PBXs might not support hunt-group overflow; in which case, the caller could
experience a ring no-answer condition until a port is available to accept the call.
3.
Remove the busy condition from all Octel Overture 200/300 port PBX extensions.
Port
Ring-No-Answer
Perform
the following steps for the port ring-no-answer test:
1.
Disconnect the 25-pair cables associated with the Octel Overture 200/300.
2.
From telephone A, enter the hunt-group extension number or access code associated with the
extensions connected to the Octel Overture 200/300.
3.
Is the call diverted to the correct alternate answer point when the Octel Overture 200/300 does not
answer?
YES Continue.
NO
Determine the cause and correct the problem before continuing.
4.
Reconnect the modular line cords.
5.
From the terminal, enter
TE C 1.
The Octel Overture 200/300 should respond, showing that each
port is forwarded until all ports have been forwarded.
6.
Enter
PS
to verify that all ports are in the
FWD
(forwarded) state.
7.
From telephone A, enter the hunt-group extension number or access code.
8.
Is the call forwarded to the correct position as specified in the call forwarding string (System
Parameter 45 — SYSTEM RELOAD FOR
W
ARD STRING)?
YES Continue.
NO
Determine the cause and correct before continuing.
9.
From the terminal, enter
TE C 2
to cancel call forwarding. The Octel Overture 200/300 should
respond with
ALL PORTS INITIALIZED.
Seitenansicht 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 667 668

Kommentare zu diesen Handbüchern

Keine Kommentare