4-46
Installation and Maintenance
Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
The
short 50-pin cable is not included in the installation kit. Order the cable separately
, one cable
for each slot.
Each line card installation kit, Part No. 740-6034-001, installs four line-card slots. T
o determine the
number of line-card installation kits to order, divide the total number of line-card slots by four
. The kit
contains the following:
One 66M4-4W connector block, Part No. PJ86001-01
Four 10-foot cables with male-to-female 25-pair connectors, Part No. SA10079-02
T
wo self-tap 10 x 5/8 PH sheet-metal screws, Part No. HH53024-01
A line-card installation kit is required if you are installing an integration card for the Octel Overture
200/300.
For more information about the installation of an integration card, refer to the appropriate chapter
in the
Integration
volume. For information about installing the EntryW
orks ACP card, refer to the
W
orks for Serenade
documentation.
Connector
Blocks
Figure 4-1
1
shows the connector block that is to be used to add wiring for the Octel Overture 200/300.
The block is supplied in the installation kit. The connector block has 50 separate punchdown contacts in
each column, with each column wired to an amphenol connector at the side of the block. Column A is
wired to jack 1, column B to jack 2, etc.
Mount the block to the backboard in the location that you have specified. Mounting screws are provided
when the block is ordered. Mount the block with the word “T
OP” (embossed in the plastic, located at the
upper left side of the block) facing up (refer to Figure 4-1
1).