Issue 5.00
2 - 66 Features
22-11 DID Assignment
. For the required incoming digits, enter 555 in 22-11-02 or 102 (Voice
mail routing) in 22-11-05 or 06 . Make a separate entry for each Night
Service mode configured.
3. Set up the Answer Tables.
Turn to Answer Tables on page 2-45 for more.
. By default, all trunks use Answer Table 1. Answer Schedule 1 is active and runs
continuously.
4. Set up the Call Routing Mailboxes.
Turn to Routing Mailbox on page 2-317 for more.
. The active schedule (Answer Table 1, Answer Schedule 1) uses Call Routing Mailbox 000.
5. Set up the Dial Action Tables.
Turn to Dial Action Table on page 2-105 for more.
. By default, Call Routing Mailbox 000 uses Dial Action Table 1.
6. Set the maximum message length for Automated Attendant callers leaving a
message in a mailbox.
47-01-03 Subscriber Message Length (Subs Msg Length)
This sets the maximum message length (1~4095 seconds) for outside
Automated Attendant callers accessing a mailbox via a LOGON or GOTO
command.
. The default setting is 120 seconds.
47-01-04 Non-Subscriber Message Length (Mbox Msg Length)
This sets the maximum message length (1~4095 seconds) for outside
Automated Attendant callers leaving a message in a Subscriber Mailboxes.
. The default setting is 120 seconds.
Operation
Using the Automated Attendant
For the outside caller:
After Automated Attendant answers, voice prompts will instruct you which digits to dial.
Seitenansicht 73