Issue 5.00
InMail System Guide 2 - 271
47-01-14 Number of Callout Attempts (Notify Call Attmpt)
Set how many times (1~99 attempts) InMail retries an incomplete Message
Notification callout. This total includes unacknowledged callouts, callouts to
a busy destination, and callouts to an unanswered destination. This option
applies to pager and non-pager callouts.
. The default setting for this option is 5 attempts.
3. Be sure Message Waiting lamp for Subscriber Mailboxes is on.
47-02-08 Message Waiting Lamp (Update MW Lamp)
Enter 1 (Yes) to enable Message Waiting lamp.
If Message Waiting lamp is disabled (0), Message Notification will not
function.
. By default, this option is 1 (Yes).
Unique Programming for Non-Pager Message Notification
1. Set the intervals InMail waits between incomplete non-pager Message
Notification callouts.
47-01-10 Wait Between Non-Pager Callout Attempts (Notify N-Pgr Intvl)
Set the minimum time (1~255 minutes) between non-pager Message
Notification callouts in which the destination answers, says “Hello,” dials 1
to acknowledge and then enters the wrong security code.
. The default for this option is 20 minutes.
47-01-11 Wait Between Busy Non-Pager Callout Attempts (Notify Busy Intvl)
Set how long InMail will wait (1~255 minutes), after it dials a busy
non-pager callout destination, before retrying the callout number.
. The default for this option is 15 minutes.